Algorithm: How Battery Controller Optimizes Your Schedule

This document explains step by step how the dynamic programming (DP) engine in Battery Controller calculates the optimal charge/discharge schedule for your battery.

For the operational side — coordinators, intervals, and why the schedule changes between runs — see How it works.

flowchart TD
    IN["<b>Inputs</b><br/>prices, PV forecast, consumption forecast,<br/>battery specs, current SoC"] --> DISC

    DISC["<b>1. Discretize</b><br/>time steps x SoC states (10 Wh)<br/>x power actions (100 W)"] --> TERM

    TERM["<b>2. Terminal condition</b><br/>V[T][s] = -(soc_kwh x feed_in_price_T)"] --> BACK

    BACK["<b>3. Backward pass</b><br/>V[t][s] = min over actions of<br/>(step_cost + V[t+1][s'])"] --> FWD

    FWD["<b>4. Forward pass</b><br/>follow best_action[t][soc]<br/>from the current SoC"] --> FILT

    FILT["<b>5. Oscillation filter</b><br/>drop charge/discharge pairs whose<br/>spread cannot cover wear + losses"] --> OUT

    BACK -.->|"lambda = -dV[0]/dSoC"| SHADOW["<b>Shadow price</b><br/>marginal value of storage"]

    OUT["<b>Schedule</b><br/>power target per 15-min step"]

    style BACK fill:#0f766e22,stroke:#0f766e
    style SHADOW fill:#b4530922,stroke:#b45309

Table of Contents

  1. Problem Statement
  2. Inputs
  3. State Space Discretization
  4. Cost Function (Step Cost)
  5. Terminal Condition
  6. Backward Pass (Backward Induction)
  7. Forward Pass (Schedule Extraction)
  8. Post-Processing Filters
  9. Shadow Price Calculation
  10. Rolling-Horizon Execution
  11. Numerical Considerations
  12. Multi-Battery Dispatch

1. Problem Statement

The optimizer answers this question for every 15-minute run:

Given the current battery state of charge (SoC) and forecasts of prices, PV production, and household consumption for the next N hours, what charge/discharge power should the battery apply at each time step to minimize total electricity cost?

"Total cost" includes: - Grid import costs (buying electricity) - Grid export revenue (selling electricity, negative cost) - Battery degradation cost (wear per full charge+discharge cycle)

The optimizer must respect physical constraints: SoC must stay within [min_soc, max_soc], and power must stay within [-max_discharge, max_charge].


2. Inputs

Input Unit Description
current_soc_kwh kWh Current battery state of charge
price_forecast[t] EUR/kWh Grid buy price for each time step
feed_in_forecast[t] EUR/kWh Grid sell (export) price for each time step
pv_forecast[t] kW AC-side PV production for each time step
pv_dc_forecast[t] kW DC-coupled PV production for each step (optional)
consumption_forecast[t] kW Expected household consumption for each step
step_durations_hours[t] h Duration of each time step (typically 0.25 h = 15 min)
degradation_cost_per_cycle EUR/cycle Battery wear cost per full charge+discharge cycle (converted to EUR/kWh by coordinator: ÷ (2 × usable_kwh) — one cycle is charge + discharge throughput)
min_price_spread EUR/kWh Minimum buy/sell spread to trigger arbitrage

Battery configuration:

Parameter Description
capacity_kwh Total battery capacity
min_soc_kwh / max_soc_kwh Operating SoC limits
max_charge_power_kw / max_discharge_power_kw Nominal power limits
charge_efficiency_curve Charge efficiency as a function of power (see §4.1)
discharge_efficiency_curve Discharge efficiency as a function of power (see §4.1)
pv_dc_coupled Whether DC-coupled PV is present
pv_dc_efficiency DC MPPT + DC-DC conversion efficiency (~0.97)
max_grid_power_kw Grid connection cap (0 = unlimited)
high_soc_charge_threshold_pct Above this SoC (%), charge is limited to high_soc_max_charge_kw
high_soc_max_charge_kw Derated charge limit above threshold (0 = no derating)
low_soc_discharge_threshold_pct Below this SoC (%), discharge is limited to low_soc_max_discharge_kw
low_soc_max_discharge_kw Derated discharge limit below threshold (0 = no derating)

3. State Space Discretization

The DP operates on a discrete grid of SoC states and power actions. Continuous SoC and power are approximated by finite grids to make the problem tractable.

3.1 SoC Grid

The SoC range [min_soc_kwh, max_soc_kwh] is divided into evenly spaced states:

soc_resolution_wh = max(SOC_RESOLUTION_WH, (max_soc_wh - min_soc_wh) / MAX_SOC_STATES)
n_soc_states = round((max_soc_wh - min_soc_wh) / soc_resolution_wh) + 1
soc_states[i] = min_soc_wh + i × soc_resolution_wh
  • SOC_RESOLUTION_WH (default: 10 Wh) is the base grid constant; the power step is derived from it.
  • MAX_SOC_STATES (default: 1000) bounds the state count. DP cost scales with n_steps × n_soc_states × n_actions, so at a fixed 10 Wh the solve time grows linearly with usable capacity — a 44 kWh usable range needs 4401 states versus 801 for an 8 kWh one, and takes proportionally longer for no added decision quality. Above the budget the resolution is coarsened so the state count stays bounded.
  • The cap engages only above 10 kWh of usable range (MAX_SOC_STATES × SOC_RESOLUTION_WH). Typical home batteries keep the exact 10 Wh grid and are unaffected.
  • At the cap the resolution is 0.1% of usable capacity (e.g. 44 Wh on a 44 kWh range), well below SoC sensor accuracy (~1%). Changing the grid does shift which SoC levels are representable, so realized savings move by a few percent in either direction — this is discretization jitter, not a systematic loss, and is inherent to any grid choice.
  • Because the power step is derived from the resolution (§3.2), a coarser grid also widens the action step, compounding the speedup on large batteries.
  • SoC boundaries are rounded to the nearest Wh to prevent floating-point comparison errors (e.g. 212.0 < 212.00000000000003).

3.2 Power Action Grid

The power step uses POWER_STEP_W as a practical minimum to prevent unprofitable trickle actions at near-marginal prices. The aligned step ensures the smallest action crosses at least one SoC state:

aligned_step_w   = soc_resolution_wh / full_step_hours   (e.g. 10 Wh / 1 h = 10 W)
power_step_w     = max(POWER_STEP_W, aligned_step_w)      (e.g. max(100, 10) = 100 W)
charge_actions   = [max_charge_w, ..., 2×step, step, 0]   (highest-first)
discharge_actions = [-step, -2×step, ..., -max_discharge_w] (lowest-first)
actions = discharge_actions + charge_actions

Boundary actions are evaluated separately for each SoC state after the main action loop to capture the residual capacity that the 100 W grid cannot reach (up to ~115 Wh per step):

drain_w = (soc_wh - min_soc_wh) × dis_eff(drain_w) / step_hours   → new_soc_idx = 0
fill_w  = (max_soc_wh - soc_wh) / (step_hours × chg_eff(fill_w)) → new_soc_idx = n_soc_states − 1

The boundary power appears on both sides (the efficiency depends on the very power being solved for), so it is found by fixed-point iteration: seed with the representative scalar, then re-evaluate the curve at the resulting power twice. The curves are smooth and the residual capacities small, so two passes converge. A single zero-power scalar would be wrong by tens of percentage points on a steep curve, because boundary powers land in exactly the steep part-load region.

new_soc_idx is set directly (not recomputed via the energy formula) to avoid floating-point errors at exact boundaries.

  • full_step_hours is the duration of a regular (non-partial) time step. A partial first step (e.g. 3 minutes remaining before the next price boundary) must not shrink power_step_w for all subsequent full steps.
  • Charge actions are listed highest-first so that the DP's "first equal wins" tie-breaking naturally produces front-loaded charging (maximum power immediately rather than a ramp-up).
  • The global action list is built from the nominal (unconstrained) maxima. Per-state derating is applied in the backward pass (see Section 6).

4. Cost Function (Step Cost)

calculate_step_cost(t, s, a) computes the cost of applying action a (W) at time step t with SoC s (Wh). All values in this section refer to a single time step of duration dt hours.

4.1 Efficiency Model

Each direction (charge / discharge) has its own power-dependent efficiency curve: a piecewise-linear function mapping AC power (kW) → efficiency (0–1).

Two physical effects act in opposite directions. Cell I²R (resistive) losses grow with current, so the battery alone gets slightly worse at high power. But in a complete system that is swamped by the inverter's fixed idle loss (roughly 30–60 W), which has to be paid out of whatever power is flowing: it consumes a third or more of the energy at 100 W and is negligible at 5 kW. Measured curves therefore rise steeply from low power and then flatten. This matters because a home battery spends much of the night discharging at 100–300 W, exactly where the curve is worst.

Configuration format: a plain scalar (e.g. 0.95) produces a flat curve valid at all power levels. A colon-separated list (e.g. 0:0.95, 5:0.92) defines breakpoints that are linearly interpolated; efficiency is clamped flat outside the specified range.

Measured curves for real hardware: see efficiency-curves.md for ready-to-paste curves for named home battery systems, based on the HTW Berlin "Stromspeicher-Inspektion 2026" lab measurements, plus guidance on deriving a curve for hardware that is not listed.

Representative scalar efficiency: some consumers need one number instead of the full curve — the oscillation filter threshold, the hybrid-mode shadow price thresholds and diagnostics. That scalar is the arithmetic mean of the curve sampled at 10 points from 5 % to 95 % of nominal power (the sampling used by the HTW Berlin efficiency guideline, so it is comparable to published mean path efficiencies), and round_trip_efficiency = charge_eff_repr × discharge_eff_repr. For a symmetric flat curve at 0.9487: RTE ≈ 0.90, identical to the pre-curve implementation.

Sampling at zero power instead would take the single worst point of a realistic curve — for a measured curve it yields RTE 0.64 where the true operating value is 0.93, inflating every threshold derived from it by ~20 % and effectively suppressing arbitrage and PV capture.

Per-action interpolation: inside the DP backward pass, each candidate action uses:

action_kw  = |action_w| / 1000
charge_eff = interpolate(charge_curve, action_kw)   # for action_w > 0
dis_eff    = interpolate(discharge_curve, action_kw) # for action_w < 0

SoC transitions use the action-specific efficiency:

charging:    new_soc = soc + action_w × dt × charge_eff
discharging: new_soc = soc − |action_w| × dt / dis_eff

Boundary actions (drain to min / fill to max) solve for the boundary power by fixed-point iteration on the curve (see §3).

Multi-battery aggregation: curves are indexed by power, so they are combined on the power axis rather than averaged at the same absolute power. Each battery carries a share of the aggregate power proportional to its own rating and is evaluated at share_i × P; the aggregated curve spans 0..Σ max_power. The two directions combine differently because efficiency enters the SoC transition differently:

charge:    eff(P) = Σ share_i × eff_i(share_i × P)
discharge: eff(P) = 1 / Σ share_i / eff_i(share_i × P)

Calibration: runtime efficiency corrections are applied as scalar multipliers to each curve point:

charge override:    [(p, min(1.0, eff × correction)) for p, eff in charge_curve]
discharge override: [(p, max(1e-6, eff / correction)) for p, eff in discharge_curve]
The corrected curves are used for SoC transitions only. The economic cost model (grid cost + degradation) always uses the nominal curves, so a charging/discharging-speed problem is not double-counted as extra energy cost or degradation. Discharge override points may exceed 1.0 after scaling; this is safe precisely because they never enter the cost model.

DC-coupled PV uses its own path efficiency (pv_dc_efficiency ≈ 0.97, MPPT only, no AC conversion).

4.2 Charging (action_w > 0)

When charging at AC setpoint P (W):

  1. AC grid draw: the grid supplies the setpoint directly; conversion losses are internal to the inverter and captured in the SoC transition:

    grid_to_battery_w = P
    ac_stored_wh      = P × dt × charge_eff
    

  2. Passive DC PV continues on top: the AC setpoint only controls AC-side exchange — DC MPPT charging is independent of it and fills the headroom that remains after the AC-charged energy:

    headroom_wh       = max(0, max_soc_wh - soc_wh - ac_stored_wh)
    passive_charge_wh = min(pv_dc_production_w × dc_eff × dt, headroom_wh)
    

  3. Remaining DC PV not absorbed by the battery flows to AC through the inverter at 96% efficiency.

  4. Throughput: (ac_stored_wh + passive_charge_wh) / 1000 kWh (for degradation).

4.3 Discharging (action_w < 0)

When discharging at setpoint P (W, negative):

usable_power_w   = |P| × discharge_eff    (power delivered to home AC side)
grid_to_battery_w = -usable_power_w       (negative = flows away from grid)
throughput_kwh    = |P| × dt / 1000

All DC PV excess flows to AC while discharging.

4.4 Idle (action_w == 0)

No explicit grid power, but DC-coupled PV still passively charges the battery up to available headroom:

headroom_wh      = max_soc_wh - soc_wh
passive_charge_wh = min(pv_dc_production_w × dc_eff × dt, headroom_wh)
throughput_kwh    = passive_charge_wh / 1000

4.5 Net Grid Exchange and Final Cost

total_ac_pv_w = pv_production_w + dc_pv_excess_w × DC_TO_AC_INVERTER_EFF
net_grid_w    = consumption_w - total_ac_pv_w + grid_to_battery_w

If max_grid_power_kw > 0, net_grid_w is clamped to [-cap, +cap].

energy_kwh = |net_grid_w| × dt / 1000

grid_cost = energy_kwh × grid_price      (if net_grid_w > 0: buying)
          = -energy_kwh × feed_in_price  (if net_grid_w < 0: selling)

degradation_cost_per_kwh = degradation_cost_per_cycle / (2 × usable_kwh)  (conversion in coordinator; a full cycle = 2 × usable_kwh throughput)
degradation_cost = throughput_kwh × degradation_cost_per_kwh

step_cost = grid_cost + degradation_cost

5. Terminal Condition

The DP looks N steps into the future. At time T (end of horizon), the battery still holds energy. Without a terminal value, the DP would irrationally discharge the battery just before the horizon ends (energy "disappears" after step N).

The terminal value of being in SoC state s is:

V[T][s] = -(stored_kwh × terminal_price)

where stored_kwh = (soc_wh - min_soc_wh) / 1000.

The negative sign is because V represents cost — more stored energy means lower cost (more future value).

Choosing terminal_price:

max(0, min(feed_in_forecast[-1], clipped average of the last 6 h of feed-in prices)) — a blended tail that dampens transient price spikes at the forecast boundary, clamped at 0 so a negative feed-in tail never penalizes stored energy (the horizon end is artificial; the battery is never forced to sell at a loss). The shadow price from the previous run is deliberately not used as terminal value: λ ≈ sqrt(RTE) × P_best, so using it would make discharge at the best price hour break-even and suppress discharge exactly at the peak (a circular dependency in rolling-horizon re-optimization). The shadow price is only used by the hybrid/hybrid+ modes as the charge/discharge (and, in hybrid+, surplus-capture) switching threshold.


6. Backward Pass (Backward Induction)

This is the core of the algorithm. It computes the value function V[t][s]: the minimum achievable total cost from time t to the end of the horizon, starting in SoC state s.

The Bellman equation is:

V[t][s] = min over all actions a of:
               step_cost(t, s, a) + V[t+1][s']

where s' is the SoC state after applying action a:

  • Charging: s' = s + a × dt × charge_eff(|a|/1000) plus passive DC PV charging up to the remaining headroom (if DC-coupled)
  • Discharging: s' = s - |a| × dt / dis_eff(|a|/1000) (energy drawn from battery, with losses)
  • Idle: s' = s (or passive DC PV charging if DC-coupled)

The backward pass runs from t = N-1 down to t = 0:

# Pre-compute per-state power limits (outside the t-loop for performance)
soc_max_charge_w[s]    = max_charge_at_soc(soc_states[s])
soc_max_discharge_w[s] = max_discharge_at_soc(soc_states[s])

for t in range(N-1, -1, -1):
    for s in all_soc_states:
        best_cost = infinity
        best_action = 0

        for a in all_actions:
            if a > 0 and a > soc_max_charge_w[s]:
                continue   # SoC-dependent charge derating
            if a < 0 and |a| > soc_max_discharge_w[s]:
                continue   # SoC-dependent discharge derating

            s' = transition(s, a, t)
            if s' < min_soc or s' > max_soc:
                continue   # SoC boundary violation
            if a != 0 and nearest_soc_idx(s') == nearest_soc_idx(s):
                continue   # sub-resolution action — skip to avoid ghost "free" moves

            cost = step_cost(t, s, a) + V[t+1][nearest_soc_idx(s')]
            if cost < best_cost:
                best_cost = cost
                best_action = a

        V[t][s] = best_cost
        policy[t][s] = best_action

SoC-dependent derating: Some batteries (e.g. Marstek Venus A) reduce their max charge/discharge power near SoC extremes (BMS absorption). The per-state limits soc_max_charge_w[s] and soc_max_discharge_w[s] are precomputed before the outer time loop using BatteryConfig.max_charge_at_soc() and max_discharge_at_soc(). For batteries without derating (the default), these equal the nominal maxima and the guards never fire.

Effect on the schedule: Because backward induction propagates future costs, the DP at step t already "knows" that entering a derated SoC zone at t+1 constrains future power. This causes the optimizer to front-load discharge before the low-SoC threshold — for example, discharging at 1200 W in earlier steps rather than running out of power at 380 W near empty.

Sub-resolution skip rule: If a non-zero action does not move the SoC to a different discrete state, the DP sees it as "free" (no change in V[t+1]) but the step cost still includes RTE losses. Allowing such actions causes spurious micro-charging/discharging at zero apparent benefit. These actions are skipped. Idle (a = 0) is exempt because passive DC PV may still move the SoC bin.

After the backward pass, V[0][s] gives the optimal total cost from now to the horizon for each starting SoC, and policy[t][s] gives the optimal action.


7. Forward Pass (Schedule Extraction)

The forward pass re-evaluates the V-table at the actual continuous SoC instead of snapping to the nearest discrete state and following the policy table. At each step it enumerates the same action set as the backward pass (including boundary actions) and picks the minimum-cost action:

current_soc = current_soc_kwh * 1000  # continuous, not snapped

for t in range(N):
    soc_idx = nearest_soc_idx(current_soc)
    best_action, best_new_soc = argmin over all actions a:
        step_cost(t, current_soc, a) + V[t+1][nearest_soc_idx(new_soc_after(a))]

    record best_action as power_schedule_kw[t]
    current_soc = best_new_soc
    soc_schedule_kwh[t+1] = current_soc / 1000

The sub-resolution skip still applies: non-zero actions that do not cross a SoC state boundary are skipped. Boundary actions (exact drain-to-min / fill-to-max) are also evaluated as in the backward pass.

This eliminates the SoC discretisation error that accumulates when the policy for a neighbouring discrete state differs from the optimal action at the true SoC.

This gives: - power_schedule_kw[t] — battery power at each step (positive = charge) - mode_schedule[t]"charging", "discharging", or "idle" - soc_schedule_kwh[t] — expected SoC at the start of each step


8. Post-Processing Filters

After the forward pass, two filters clean up the schedule.

8.1 Oscillation Filter

The DP sometimes schedules rapid charge↔discharge switches that are technically cost-optimal within the discrete state space but produce excessive battery cycling with little financial benefit.

Minimum profitable spread: For arbitrage to be worthwhile, the discharge price must exceed the charge price by at least:

_rte      = chg_eff_repr × dis_eff_repr   # representative RTE scalar (see §4.1)
min_arbitrage_spread = (2 × degradation_cost_per_kwh + min_price_spread) / sqrt(_rte)

The representative scalar (mean over 5..95 % of nominal power) is used rather than the zero-power value, which would overstate the required spread by ~20 % on a realistic curve and strip profitable arbitrage pairs.

Algorithm: Iterative lookahead scan (repeated until no more changes):

for each step i:
    if mode[i] == "charging":
        search steps i+1 to i+window for the next "discharging" step j
        effective_spread = discharge_price[j] - charge_cost[i] / RTE
        if effective_spread < min_arbitrage_spread:
            suppress step i (set to idle)
            mark changed = True

    if mode[i] == "discharging":
        search steps i+1 to i+window for the next "charging" step j
        effective_spread = discharge_price[i] - charge_cost[j] / RTE
        if effective_spread < min_arbitrage_spread:
            suppress step i (set to idle)
            mark changed = True

When there is a PV surplus at a charging step (PV production > consumption), the charge cost is the feed-in opportunity cost (what could have been earned by exporting that PV) rather than the grid buy price.

DC-coupled PV: Passive DC PV charging happens regardless of the AC setpoint (idle and active charging alike), so the commanded charge power is AC-only and the filter prices it directly against the PV-surplus/grid blend — no passive-DC deduction is needed.

The window size is max(2 h, battery_capacity / max_discharge_power) — larger batteries need a wider window because a full charge/discharge cycle takes longer.

After suppression, the SoC schedule is recalculated to remain consistent.

8.3 PV Curtailment Override

When the PV Curtailed switch is enabled in the integration, the coordinator zeroes both pv_forecast and pv_dc_forecast before passing them to the optimizer. This corrects for the case where solar inverters automatically shut down at negative feed-in prices, leaving the controller with a phantom PV production in its forecast.

Effect on the optimizer: - net_load is higher (consumption is no longer offset by PV) → more incentive to charge at negative prices. - DC PV passive charging is removed from SoC transitions → the DP no longer expects "free" battery top-up from the sun. - With negative prices the optimal action is charging from the grid; zeroing PV ensures the planned charge rate is not artificially reduced by expected solar contribution.

Effect on real-time control: - Zero-grid mode: instead of reacting to the live grid sensor (which would trigger discharging to cover load), the controller follows the DP schedule. With negative prices and zeroed PV that schedule is charging, not discharging. - Hybrid/follow-schedule: unchanged — the corrected forecast is already reflected in the optimizer output.

This flag is a manual override, intended to be toggled by a Home Assistant automation that watches the inverter's export-limitation status sensor.


8.2 Micro-Cycle Filter

Very short charge or discharge segments (e.g. a single 15-minute slot) move so little energy that degradation cost per kWh becomes disproportionately high. Any contiguous block of charging or discharging that moves less than MIN_CYCLE_KWH (default: 0.2 kWh) is replaced with idle. If no micro-cycles are found, the filter returns the schedule unchanged without rebuilding.


9. Shadow Price Calculation

The shadow price λ is the marginal value of one additional kWh stored in the battery right now. It is derived numerically from the value function using a central difference:

λ = -dV[0]/dSoC = (V[0][s-1] - V[0][s+1]) / (2 × ΔSoC_kWh)
  • V is cost (lower is better), so adding energy reduces cost → the gradient is negative → λ is positive.
  • For boundary SoC states, a one-sided difference is used.

Interpretation: Let chg_r = chg_eff_repr and dis_r = dis_eff_repr (representative scalars, §4.1): - If the current grid buy price is less than λ × chg_r, it is profitable to charge — 1 kWh bought from AC stores chg_r kWh worth λ each. - If the current feed-in price is greater than λ / dis_r, it is profitable to discharge/export — 1 stored kWh yields dis_r kWh on the AC side.

Charge-speed correction: when runtime calibration detects that the battery gains less SoC per time step than modelled, the optimizer reduces the charge-side efficiency curve for the planned SoC transitions. Economic quantities (step costs, the oscillation-filter threshold) keep using the nominal curves.

The shadow price is always the raw DP value — there is no separate "post-processed" shadow price. Post-processing filters affect total_cost and savings (where the difference between raw and processed values shows the impact of filtered actions), but the shadow price is a DP concept that is not modified by post-processing.

Use by hybrid mode: λ is used by the coordinator as the charge/discharge switching threshold in hybrid mode. It is deliberately not fed back into the next run's terminal condition (see Section 5).

Use by hybrid+ mode: hybrid+ additionally uses λ to gate PV-surplus capture. Plain hybrid stores any surplus as soon as it appears; hybrid+ only stores it when λ × sqrt(RTE) exceeds the current feed-in price. Because λ already prices in upcoming cheap-surplus hours (e.g. a midday PV peak coinciding with low prices), a low λ means the battery can be filled more cheaply later — so the current surplus is exported at the (higher) feed-in price instead, with a ±5% hysteresis band around the threshold to prevent oscillation.

Conversely, when little future surplus is forecast, λ stays high: every kWh not captured now would have to be bought from the grid later, or is missing during expensive evening hours. The threshold λ × sqrt(RTE) ≥ feed-in is then met and hybrid+ captures the surplus immediately — identical to plain hybrid. No separate rule is needed; the shadow price encodes "how cheaply can the battery still be filled later" by construction. Exporting only wins when the battery would fill up anyway (little headroom relative to the forecast surplus) or when stored energy has little future value (flat prices, no discharge opportunity).


10. Rolling-Horizon Execution

The optimizer runs every 15 minutes, plus on a handful of event-driven triggers (new price period, a significant price change, a stale price/SoC sensor recovering, and a scheduled mid-period correction run at the midpoint of the current price period — see coordinator_optimization.py). Each run:

  1. Reads the current SoC and latest forecasts.
  2. Calls optimize_battery_schedule() with the latest forecasts and calibration overrides, re-solving the entire horizon from scratch (the terminal condition is derived fresh from the feed-in forecast each time — see Section 5 — not carried over from the previous run's shadow price).
  3. Executes only the first step of the resulting schedule (optimal_power_kw).
  4. Exposes the new shadow price for hybrid-mode thresholding and diagnostics.

This is called a rolling horizon or receding horizon approach. Re-optimizing every 15 minutes (or sooner, on the triggers above) allows the schedule to adapt as prices are updated, PV production deviates from forecast, or household consumption changes.

Because capacity is limited, each full re-solve is a global allocation across every cheap/negative-price opportunity in the horizon — how much of the current window to use now versus reserve for a better one later. A small change in inputs between two runs (price forecast update, revised PV/consumption forecast, or actual SoC drifting from the previous plan) can shift that allocation enough that two runs a few minutes apart show a visibly different schedule for what looks like an unchanged situation. This is expected, not a bug.

Convergence

The DP itself is stateless between runs — there is no shadow-price carry-over — but two things it depends on do build up from HA recorder history over time: - The historical price model (used before day-ahead prices are published, and to extend a short horizon) improves as more price/weather data accumulates. - The household consumption pattern needs several weeks of kWh sensor history to build accurate forecasts.

While these are still calibrating (first 2–4 weeks), forecasts are noisier, so the schedule may change more noticeably between runs — including between two runs within the same 15-minute slot — and may appear more aggressive than the long-run optimum.


11. Numerical Considerations

Several implementation details prevent subtle correctness bugs:

Issue Fix
Floating-point SoC boundary min_soc_wh = round(capacity × min_pct / 100 × 1000) — avoids 212.0 < 212.00000000000003
Sub-resolution actions Skip any non-idle action that doesn't cross a SoC state boundary
Partial first step Use step_durations_hours[1] (not min(step_durations_hours)) to compute power_step_w; optimizer always uses step 0 as the immediate setpoint (primary runs are at period boundaries so step 0 is full)
Horizon-end discharge Terminal condition V[T][s] = -stored_kwh × terminal_price prevents horizon-end drain
Feed-in price None Coordinator always falls back to CONF_FIXED_FEED_IN_PRICE; returning None would cause the DP to use the grid buy price, making PV arbitrage always unprofitable
Efficiency curve scalar round_trip_efficiency = chg_eff_repr × dis_eff_repr, each the mean of its curve over 5..95 % of nominal power — never the zero-power value, which is the worst point of a realistic curve
Derating precomputed outside t-loop soc_max_charge_w[s] and soc_max_discharge_w[s] are arrays computed once from soc_states before the backward pass, avoiding repeated method calls in the tight inner loop

12. Variable Price Intervals (15-min / 30-min / hourly)

The DP is fully interval-agnostic: all energy quantities are scaled by step_durations_hours[t], so the same algorithm handles 15-minute, 30-minute, and hourly prices without modification.

How the interval is detected

helpers.py auto-detects the price interval from the sensor's attributes:

  1. Sensors with per-entry timestamps (net_prices_today, raw_today, etc.): the delta between the first two start timestamps determines the interval (15, 30, or 60 min).
  2. Sensors without timestamps (today, tomorrow, bare float lists): defaults to 60 min.

Detection happens in _detect_interval_from_entries(). The result flows into: - extract_price_forecast_with_timestamps() → returns (prices, start_times, interval_minutes) - compute_step_durations_hours() → computes per-step durations aligned to price boundaries

Scheduling

The optimizer runs are event-driven, synchronised to the price sensor:

Trigger When Purpose
_handle_price_change (period boundary) start_times[0] changes Primary run; step 0 is always a full interval
Mid-period correction period_start + interval/2 Corrects SoC drift from the primary run
DC coordinator fallback 60-min interval Safety net if above triggers miss

For sensors without timestamp attributes the fallback is a >10% price-change threshold.

Step duration alignment

The first DP step covers only the remaining time within the current price slot (partial interval). All subsequent steps are full intervals. This prevents energy miscalculation at price boundaries.

Because primary runs fire at period boundaries, step 0 is always (or nearly always) a full interval. The partial-step case only occurs on HA restarts mid-period or during mid-period correction runs; in both cases the DP step 0 action is used directly.

Price interval Steps per day First step Full steps DP table size
60 min 24 ≤ 60 min 1 h = 1.0 h each 24 × SoC states
30 min 48 ≤ 30 min 0.5 h each 48 × SoC states
15 min 96 ≤ 15 min 0.25 h each 96 × SoC states

PV and consumption resampling

PV production and household consumption forecasts are emitted by the forecast coordinator at FORECAST_INTERVAL_MINUTES (15-minute) resolution, aligned to quarter-hour boundaries starting at the current step. The weather input (open-meteo) is hourly; hourly series are expanded to 15-minute steps by repetition (mean-preserving), while the solar-geometry model is evaluated per 15-minute timestamp, so dawn/dusk ramps gain sub-hourly shape even from hourly radiation data. Consumption comes from hourly pattern buckets and is expanded by repetition too.

The optimization coordinator resamples from the pipeline's native interval (published as forecast_interval_minutes in the coordinator data; 60 is assumed for data from older versions) to the price interval:

  • resample_forecast(pv_forecast_kw, forecast_interval_minutes, price_interval) — repetition when upsampling, weighted-average when downsampling
  • Because the forecast series starts at the current quarter-hour (not the current hour), step k of the forecast aligns with price period k for 15-minute price intervals — previously hourly-based series could be misaligned by up to 45 minutes at hour boundaries

Past-entry exclusion for timestamp-bearing sensors

For sensors like Nordpool raw_today (96 entries per day with explicit start timestamps), past entries are skipped by comparing each entry's start + interval against now. This is identical to the net_prices_today handling and correctly excludes elapsed 15-min slots regardless of the current minute within an hour.


13. Baseline Cost and Savings

The baseline cost represents the electricity cost without any battery. In this scenario: - All consumption is met directly from the grid - All AC PV surplus is exported at the feed-in price - DC-coupled PV panels still produce, but without a battery to absorb the DC output, all DC PV goes through the inverter to AC (at DC_TO_AC_INVERTER_EFFICIENCY)

Raw vs processed costs: The optimizer reports both raw (DP-derived) and post-processed costs: - raw_total_cost: V[0][current_soc_idx] from the DP value function - total_cost: Recalculated from the filtered schedule via _calculate_schedule_total_cost - The difference shows the impact of post-processing filters (typically < 0.01 EUR when no actions are filtered, due to floating-point differences in SoC reconstruction) - savings = baseline_cost - initial_terminal_value - total_cost


14. Summary

Inputs: SoC, price/PV/consumption forecasts, battery config
[3] Discretize SoC (grid of states) and power (grid of actions)
[5] Set terminal condition V[T][s] = -(stored_kwh × terminal_price)
[6] BACKWARD PASS (t = N-1 → 0)
    For each (t, s): V[t][s] = min_a { step_cost(t, s, a) + V[t+1][s'] }
    Store optimal action in policy[t][s]
[7] FORWARD PASS
    Trace policy from current SoC → power/mode/SoC schedule
[8] Post-processing
    Oscillation filter: remove unprofitable charge↔discharge switches
    Micro-cycle filter: suppress tiny charge/discharge blocks
[9] Compute shadow price λ from V[0] gradient
Output: power_schedule_kw, mode_schedule, soc_schedule_kwh,
        shadow_price_eur_kwh, savings estimate
[10] Execute step 0, save λ, wait 15 min, repeat

12. Multi-Battery Dispatch

The DP optimizer treats all configured batteries as a single aggregated virtual battery (aggregate_battery_configs). After the optimizer produces a combined setpoint, _split_setpoint distributes it across the individual inverters.

SoC-gap triggered concentration

The dispatch strategy is determined by the relative-SoC gap between batteries:

rel_soc_i = (soc_i - min_soc_i) / (max_soc_i - min_soc_i)   ∈ [0, 1]
gap = max(rel_soc) − min(rel_soc)
Gap Strategy
gap < 0.10 Concentrate on one battery
gap ≥ 0.10 Proportional split to rebalance

Why concentration at low gap: splitting a small setpoint (e.g. 100 W) across two inverters results in each receiving ~50 W. Most home battery inverters are inefficient at very low power (high fixed conversion losses relative to throughput). Concentrating on one inverter avoids this and provides more stable real-time tracking in zero-grid mode.

Why proportional split at high gap: when SoC has diverged, one battery is being disproportionately cycled. Proportional splitting (weighted by available headroom/energy) rebalances the SoC levels over time.

Battery selection for concentration

When concentrating, which battery is chosen depends on the control mode:

Mode Selection criterion
zero_grid / hybrid / hybrid_plus Closest to 50% rel_soc — can handle charge and discharge direction changes longest without hitting a SoC limit
Scheduled charge Lowest rel_soc (most headroom)
Scheduled discharge Highest rel_soc (most energy available)

Hysteresis: the active battery only changes when the best candidate's score exceeds the current battery's score by more than _SOC_HYSTERESIS = 0.05. This creates three zones:

gap < 0.05   → concentrate, no switch (hysteresis holds)
0.05 ≤ gap < 0.10 → concentrate, switch to better battery
gap ≥ 0.10   → proportional split, reset active battery selection

Power-overflow redistribution

Within the proportional split path, batteries that reach their max_charge_power_kw or max_discharge_power_kw limit have the overflow redistributed iteratively to the remaining batteries. This ensures the combined setpoint is fully absorbed even when one inverter is at its power limit.