Configuration Reference

Quick reference for all configuration parameters.

Basic Parameters

Parameter Type Range Default Description
area_m2 float 50-500 150 Heated floor area (m²)
energy_label select A+++-G C Building energy efficiency rating
glass_east_m2 float 0-50 5 East-facing window area (m²)
glass_west_m2 float 0-50 5 West-facing window area (m²)
glass_south_m2 float 0-50 10 South-facing window area (m²)
glass_u_value float 0.5-3.0 1.2 Window thermal transmittance (W/m²K)

Heat Pump Parameters

Parameter Type Range Default Description
base_cop float 2.0-6.0 3.5 COP at A7/W35 reference condition
k_factor float 0.01-0.10 0.03 COP degradation per °C supply temp increase
cop_compensation_factor float 0.5-1.2 0.9 System efficiency adjustment factor

Sensor Configuration

Parameter Type Required Description
consumption_sensor entity_id Yes Electricity consumption sensor (W or kW)
production_sensor entity_id No Electricity production sensor (W or kW)
consumption_price_sensor entity_id No* Electricity consumption price (€/kWh)
production_price_sensor entity_id No Feed-in tariff price (€/kWh)

* Required for price optimization, optional for COP-only optimization

Advanced Parameters

Parameter Type Range Default Description
planning_window_hours integer 2-24 6 Optimization planning horizon (hours)
time_base_minutes integer 15-120 60 Optimization time step (minutes)
max_buffer_debt float 0-20 5.0 Maximum heat debt (kWh) for cost optimization
offset_delta_t integer 10-60 10 Minutes per °C offset change (controls change speed)
min_supply_temp float 20-45 25 Minimum supply temperature (°C)
max_supply_temp float 35-60 50 Maximum supply temperature (°C)
min_outdoor_temp float -20-5 -10 Minimum outdoor temperature for heating (°C)
max_outdoor_temp float 5-20 18 Maximum outdoor temperature for heating (°C)

Temperature Control Parameters

Parameter Type Range Default Description
target_indoor_temp float 15-25 20.0 Target indoor temperature setpoint (°C)
indoor_temp_hysteresis float 0.1-2.0 0.5 Hysteresis band for heat demand modulation (°C)

Offset Change Speed (offset_delta_t) Explained

The offset_delta_t parameter controls how quickly the heating curve offset can change:

  • 10 min/°C (default): Fast changes, max 6°C per hour (at 60-min time base)
  • 30 min/°C: Moderate changes, max 2°C per hour
  • 60 min/°C: Slow changes, max 1°C per hour

Formula: max_offset_change = time_base_minutes / offset_delta_t

Use cases: - Lower values (10-20): Responsive to price changes, good for volatile markets - Higher values (30-60): Smoother operation, reduces system stress

Heat Demand Modulation

When target_indoor_temp and indoor_temp_hysteresis are configured with an indoor temperature sensor, heat demand is automatically modulated:

Indoor Temp Position Heat Demand Factor
Below (target - hysteresis) > 1.0 (increased proportionally)
Within hysteresis band 0.0 to 1.0 (linear interpolation)
Above (target + hysteresis) 0.0 (no heat demand)

Maximum Heat Debt Explained

The max_buffer_debt parameter controls how much the optimizer can reduce heating during expensive hours with the promise to compensate later:

  • 0 kWh: No heat debt allowed - always meet demand immediately (conservative)
  • 5.0 kWh (default): Moderate debt - good balance between cost savings and comfort
  • 10+ kWh: Aggressive optimization - may affect comfort if not carefully monitored

How it works: - During expensive hours: Reduce heating, creating "heat debt" (building cools slightly) - During cheap hours: Extra heating to repay debt (building warms back up) - Net result: Same total heat, lower electricity costs

Comfort impact: Higher debt limits allow more temperature variation. Monitor closely!

Energy Label to U-Value Mapping

Energy Label U-Value (W/m²K) Building Quality
A+++ 0.18 Passive house
A++ 0.25 Excellent
A+ 0.35 Very good
A 0.45 Good
B 0.60 Above average
C 0.80 Average (default)
D 1.00 Below average
E 1.40 Poor
F 1.80 Very poor
G 2.50 Minimal

Configuration via YAML

Configuration is done via UI only (no YAML support for initial setup). However, you can modify via:

# Developer Tools → Services
service: homeassistant.update_config_entry
target:
  config_entry_id: "your_entry_id"
data:
  options:
    base_cop: 4.0
    k_factor: 0.028

Or via UI: Settings → Devices & Services → Heating Curve Optimizer → Configure


For detailed explanation of each parameter, see Configuration Guide.